Test 2017-04-13-4-1 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 210886
DEA: 050F7004
EFIS: 0500000049
DIST-CO-RTE-PM05-MON-68-R17.4/R18.0
Work DescriptionWIDENING BRIDGE
Location DescriptionIN MONTEREY COUNTY ON ROUTE 68 NEARSALINAS FROM 0.2 MILE EAST OFRESERVATION ROAD UNDERCROSSING TO SPRECKELS BOULEVARD UNDERCROSSING
Sample Information
Sample Taken Date4/13/2017 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/13/2017
Sample typeQuality Assurance A brief description of the sampleBartec Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byJason Last name of sampler or witnessed byWilcox
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameHarris Rebar Dextra Nucor Transportation Laboratory (TL) NumberC680514
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar Manufacturernucor
Coupler ManufacturerDextra America Intermediate Assembler or FabricatorUnknown
Rebar Size#5 Coupler Model Threaded
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)DL13106033, 3669 Rebar Heat Number(s)SE17100056
Rebar Size 2 Not set
Test Details
DIME Sample ID: 2017-04-13-4
DIME Test ID: 2017-04-13-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2017-04-25
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/18/2017
UTM: 75KIP
Halo ID: Small
Temperature:72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11C01#5/16mm0.31-0.00062883793023Service SpliceFred

General comments (publicly viewable) (Max 250 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 04/18/2017