Summary for Test 2017-04-17-2-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 212164
DEA: 051J1304
EFIS: 0517000064
DIST-CO-RTE-PM05-MON,MON-1-45.52, 45.4/45.8
Award Date02/16/2017
Closeout Date10/25/2019
Work DescriptionPfeiffer Canyon Emergency Bridge Replacement Project
Location DescriptionHighway 1 at Pfeiffer State Park
QA Service Level1 (Verified on 02/27/2017)

Sample Information

Sample Taken Date04/17/2017 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/18/2017
Sample typeQuality Assurance A brief description of the sampleBartec Couplers
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byED Last name of sampler or witnessed byFleming
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHarris Rebar Nucor Transportation Laboratory (TL) NumberC741370
Inspector Lot Number from the Transportation Laboratory (TL) FormB1015617 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDextra America Intermediate Assembler or FabricatorUnknown
Rebar Size#9 Coupler Model Threaded
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorNucor
Coupler Component Heat/Lot Number(s)DL14106985, 3715 Rebar Heat Number(s)SE16105372
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2017-04-17-2
DIME Test ID: 2017-04-17-2-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2017-04-25

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 04/18/2017
UTM: 2000KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
13C01#9/29mm109403194031Service SpliceBrian

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 4/18/2017