Summary for Test 2017-04-07-1-1
Test performed: ASME B1.2-83r01Project Information
Project Identifiers | Project ID: 211076 DEA: 040K6914 |
---|---|
DIST-CO-RTE-PM | 04-SF-80-8.2/8.6 |
Award Date | 12/11/2015 |
Closeout Date | 08/22/2018 |
Work Description | Install grease caps and repair pre-stress tendon |
Location Description | In SF at the eastern span of the SF-Oakland Bay Bridge |
QA Service Level | 1 (Verified on 12/01/2015) |
Sample Information
Sample Taken Date | 04/07/2017 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 04/10/2017 |
Sample type | Quality Assurance | A brief description of the sample | 5/8 various length Bolt Assy |
The quantity of what the sample constitutes | 1508 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Stacey | Last name of sampler or witnessed by | Davis |
Title of sampler | QAI | Telephone number of sampler | 562 480-6984 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Bay Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B362-025-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 8256-01 8256-02 8256-03 8256-04 8256-05 |
---|---|---|---|
Heat Number(s) | 10454540, NF16201531, 10363530, NF14101948, RR128726 | Nut Mfg. Lot Number(s) | 372874A |
Washer Mfg. Lot Number(s) | 0716-292 | Bolt Specification | A325 |
Bolt Length(s) | 1 3/4" 2" 2-1/4" 3" 3-1/4" | Nut Specification | A563 Grade DH |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 5/8" | Bolt Mfg. Lot Number | 777977, 374881A, 747736, 352106A, 132556A |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2017-04-07-1
DIME Test ID: 2017-04-07-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Test Release Date: 2017-04-25
Test Results
Input Type: Calculated
Tester's full name: Arnold Viken
Date of test: 04/18/2017
Sample No.: 1A
Rocap Number: 8256-01
Heat Number(s): no data
Mfg. Lot Number: 777977
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: A325 LE USA
Size: 0.625 in
Bolt Length: 1.75 in
Gage Type: Pass
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/18/2017 ✔