Summary for Test 2017-04-17-3-2
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 212164 DEA: 051J1304 EFIS: 0517000064 |
---|---|
DIST-CO-RTE-PM | 05-MON,MON-1-45.52, 45.4/45.8 |
Award Date | 02/16/2017 |
Closeout Date | 10/25/2019 |
Work Description | Pfeiffer Canyon Emergency Bridge Replacement Project |
Location Description | Highway 1 at Pfeiffer State Park |
QA Service Level | 1 (Verified on 02/27/2017) |
Sample Information
Sample Taken Date | 04/17/2017 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/18/2017 |
Sample type | Quality Assurance | A brief description of the sample | Bartec Couplers |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | ED | Last name of sampler or witnessed by | Fleming |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Harris Rebar Nucor | Transportation Laboratory (TL) Number | C741371 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B1015717 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Nucor |
Coupler Manufacturer | Dextra America | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | #11 | Coupler Model | Threaded |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Nucor |
Coupler Component Heat/Lot Number(s) | DL14108042, 3775 | Rebar Heat Number(s) | SE17100144 |
Rebar Size 2 | Not set | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2017-04-17-3
DIME Test ID: 2017-04-17-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2017-04-25
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 04/18/2017
UTM: 2000KIP
Halo ID: Small
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 2 | C02 | #11/36mm | 1.56 | 0 | 146466 | 93888 | Service Splice | Brian |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 4/18/2017 ✔