Summary for Test 2017-04-11-1-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 212164 DEA: 051J1304 EFIS: 0517000064 |
---|---|
DIST-CO-RTE-PM | 05-MON,MON-1-45.52, 45.4/45.8 |
Award Date | 02/16/2017 |
Closeout Date | 10/25/2019 |
Work Description | Pfeiffer Canyon Emergency Bridge Replacement Project |
Location Description | Highway 1 at Pfeiffer State Park |
QA Service Level | 1 (Verified on 02/27/2017) |
Sample Information
Sample Taken Date | 04/11/2017 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 04/12/2017 |
Sample type | Quality Assurance | A brief description of the sample | UBS hoop |
The quantity of what the sample constitutes | 142 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Stacey | Last name of sampler or witnessed by | Davis |
Title of sampler | QAI | Telephone number of sampler | 5624806984 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Harris Rebar Nucor | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B362-027-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | SE17101189 |
Hoop Manufacturer Lot Number(s) | H01 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 8 |
Diameter of Hoop | 4'-2" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Nucor Seattle |
Welding Company | Harris Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2017-04-11-1
DIME Test ID: 2017-04-11-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-04-24
Test Results
Number of Samples: 3
Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 04/14/2017
UTM: 2000KIP
Temperature: 72 f
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | H01 | #8 | 0.79 | 75779 | 95924 | OK Necking | Brian |
2 | 2 | H01 | #8 | 0.79 | 75859 | 96025 | OK Necking | Brian |
3 | 3 | H01 | #8 | 0.79 | 76209 | 96468 | OK Necking | Brian |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/17/2017 ✔