Summary for Test 2017-04-01-6-1

Test performed: AGGLP SIEVE_ANALYSIS-1

Project Information

Project IdentifiersProject ID: 212345
DEA: 044G2204
EFIS: 0412000314
DIST-CO-RTE-PM04-SON-12-17.75-18.20
Award Date12/06/2017
Closeout Date03/12/2021
Work DescriptionPROJECT: SONOMA 12 FARMERS LANE MEDIAN BARRIER MICROPILES
Location DescriptionIN SONOMA COUNTY ON ROUTE 12, IN SANTA ROSA FROM FARMERS LANE TO BRUSH CREEK RD.
QA Service Level1 (Verified on 10/18/2017)

Sample Information

Sample Taken Date04/01/2017 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/10/2017
Sample typeQuality Control A brief description of the sampleFOUNDATION
The quantity of what the sample constitutes1 BAG From where was the sample collectedJob Site
First name of sampler or witnessed bySAMUEL Last name of sampler or witnessed byAWAD
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identification17SOIL-0075 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameNA Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedA-17-002
Where the material sample would have been placed if not sampled5 TO 15 FT

Test Details

DIME Sample ID: 2017-04-01-6
DIME Test ID: 2017-04-01-6-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AGGLP SIEVE_ANALYSIS-1: Soils for Corrosion Sieve Analysis
Test Release Date: 2017-04-18

Test Results


Input Type: Measured
Tester's full name: Phillip Montes
Date of test: 04/11/2017
Total mass of material in the sample: 2592 grams
Cumulative mass retained on the 2 in. sieve: 0 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0 grams
Cumulative mass retained on the 1 in. sieve: 0 grams
Cumulative mass retained on the 3/4 in. sieve: 0 grams
Cumulative mass retained on the 1/2 in. sieve: 7 grams
Cumulative mass retained on the 3/8 in. sieve: 10 grams
Cumulative mass retained on the #4 sieve: 61 grams
Cumulative mass retained on the #8 sieve: 13 grams
Total sample mass passing the #4 sieve: 1198 grams
Total mass of fine material in the sample: 298 grams
Cumulative mass retained on the pan: 285 grams
Total cumulative mass of coarse aggregate: 78 grams
Total cumulative mass of fine aggregate: 298 grams
Sum of coarse and fine aggregate: 1276 grams
Percentage of coarse material: 6 %
Percentage of fine material: 94 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 99 %
Cumulative percent passing the 3/8 in. sieve: 99 %
Cumulative percent passing the #4 sieve: 94 %
Cumulative percent passing the #8 sieve: 90 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/11/2017