Summary for Test 2017-03-31-6-4

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 211004
DEA: 05330784
EFIS: 0512000076
DIST-CO-RTE-PM05-SLO-46-46.0/50.2
Award Date02/10/2016
Closeout Date10/15/2019
Work DescriptionCONVERT 2-LANE TO 4 LANE EXPRESSWAY.
Location DescriptionNEAR SHANDON FROM 0.2 MILE EAST OF MCMILLIAN CANYON ROAD TO 0.4 MILE WEST OF LUCY BROWN ROAD
QA Service Level1 (Verified on 01/08/2016)

Sample Information

Sample Taken Date03/31/2017 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/04/2017
Sample typeQuality Assurance A brief description of the samplefastener Assembly
The quantity of what the sample constitutes42 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byFlyGare
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameUIS Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s) Nut Mfg. Lot Number(s)15-40-006
Washer Mfg. Lot Number(s)D2290 Bolt SpecificationA325
Bolt Length(s)5.5", 4.5" Nut SpecificationA563-DH
Washer SpecificationF436 FinishHDG
Diameter/Size3/4" Bolt Mfg. Lot NumberBG0229, 762834
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2017-03-31-6
DIME Test ID: 2017-03-31-6-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-04-13

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 04/05/2017
UTM: 400KIP
Temperature: 71 F
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
14BB76-031-17?\"50700225.52Nut Proof LoadBrian

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point File

Test was verified on 4/6/2017