Summary for Test 2017-03-31-6-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 211004 DEA: 05330784 EFIS: 0512000076 |
---|---|
DIST-CO-RTE-PM | 05-SLO-46-46.0/50.2 |
Award Date | 02/10/2016 |
Closeout Date | 10/15/2019 |
Work Description | CONVERT 2-LANE TO 4 LANE EXPRESSWAY. |
Location Description | NEAR SHANDON FROM 0.2 MILE EAST OF MCMILLIAN CANYON ROAD TO 0.4 MILE WEST OF LUCY BROWN ROAD |
QA Service Level | 1 (Verified on 01/08/2016) |
Sample Information
Sample Taken Date | 03/31/2017 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/04/2017 |
Sample type | Quality Assurance | A brief description of the sample | fastener Assembly |
The quantity of what the sample constitutes | 42 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | FlyGare |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | 15-40-006 | |
Washer Mfg. Lot Number(s) | D2290 | Bolt Specification | A325 |
Bolt Length(s) | 5.5", 4.5" | Nut Specification | A563-DH |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 3/4" | Bolt Mfg. Lot Number | BG0229, 762834 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2017-03-31-6
DIME Test ID: 2017-03-31-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2017-04-13
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 04/05/2017
UTM: 400KIP
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1A | B76-031-17 | 3/4\" | 47605 | 211.8 | 10 | A325 | Brian |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 4/6/2017 ✔