Test 2017-03-27-2-1 (CONCLP 3-16) Summary

Project Information
Project IdentifiersProject ID: 211504
DEA: 060N9904
EFIS: 0612000114
DIST-CO-RTE-PM06-FRE,MAD-41U-33.1/33.4,0.0/0.3
Work DescriptionBRIDGE SCOUR MITIGATION, SEISMIC RETROFIT AND UPGRADE RAIL.
Location DescriptionFRESNO AND MADERA COUNTIES NEAR FRESNO FROM 0.1 MILE NORTH OF PERRIN ROAD UNDERCROSSING TO 0.1 MILE SOUTH OF AVENUE 9 UNDERCROSSING
Sample Information
Sample Taken Date3/27/2017 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing3/27/2017
Sample typeQuality Control A brief description of the samplepolyester resin
The quantity of what the sample constitutes80 drums From where was the sample collectedSource
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byNunes
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility namekwik Bond, Benecia Transportation Laboratory (TL) Numberc594923
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypePolyester Mfg. Lot Number(s)1039800
Batch number1039800 Mix number3232
Test Details
DIME Sample ID: 2017-03-27-2
DIME Test ID: 2017-03-27-2-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2017-05-25
Test Results

Input Type: Calculated
Tester's full name: Mike Mullins
Date of test: 03/30/2017
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 104 cps
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.08
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 61 %
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 2733 psi
Styrene ASTM D 2369 40% to 50 %: 38.3 %
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 606 psi
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.14 grams
General comments (publicly viewable) (Max 1000 characters): accepted on QC results

Test was verified on 05/25/2017