Test 2017-03-12-1-1 (AGGLP SIEVE_ANALYSIS-1) Summary

Project Information
Project IdentifiersProject ID: 212238
DEA: 11288824
EFIS: 1115000068
DIST-CO-RTE-PM11-SD-905,125,905-9.6/11.4
Work DescriptionCONSTRUCT FREEWAY TO FREEWAY CONNECTORS.
Location DescriptionSAN DIEGO COUNTY IN AND NEAR SAN DIEGO AT ROUTE 11/125/905 SEPARATION
Sample Information
Sample Taken Date3/12/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing3/22/2017
Sample typeQuality Control A brief description of the sampleBRIDGE PIER FOUNDATION
The quantity of what the sample constitutes1 BAG From where was the sample collectedJob Site
First name of sampler or witnessed byNICOLA Last name of sampler or witnessed byBERNARD
Title of samplerUnknown Laboratory sample identification17SOIL-0070
The fabricator/manufacturer/facility nameNA Transportation Laboratory (TL) NumberC585219A
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedRC-17-3902
Where the material sample would have been placed if not sampled0 TO 15 FT
Test Details
DIME Sample ID: 2017-03-12-1
DIME Test ID: 2017-03-12-1-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AGGLP SIEVE_ANALYSIS-1: Soils for Corrosion Sieve Analysis
Test Release Date: 2017-04-05
Test Results

Input Type: Measured
Tester's full name: Phillip Montes
Date of test: 03/29/2017
Total mass of material in the sample: 3378 grams
Cumulative mass retained on the 2 in. sieve: 0 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0 grams
Cumulative mass retained on the 1 in. sieve: 0 grams
Cumulative mass retained on the 3/4 in. sieve: 0 grams
Cumulative mass retained on the 1/2 in. sieve: 8 grams
Cumulative mass retained on the 3/8 in. sieve: 36 grams
Cumulative mass retained on the #4 sieve: 105 grams
Cumulative mass retained on the #8 sieve: 27 grams
Total sample mass passing the #4 sieve: 1536 grams
Total mass of fine material in the sample: 765 grams
Mass retained on the pan (fine aggregate): 738 grams
Total cumulative mass of coarse aggregate: 149 grams
Total cumulative mass of fine aggregate: 765 grams
Sum of coarse and fine aggregate: 1685 grams
Percentage of coarse material: 9 %
Percentage of fine material: 91 %
Cumulative percent passing the 2 in. sieve:100 %
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:100 %
Cumulative percent passing the 1/2 in. sieve:100 %
Cumulative percent passing the 3/8 in. sieve:97 %
Cumulative percent passing the #4 sieve:91 %
Cumulative percent passing the #8 sieve:88 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 03/29/2017