Test 2017-03-23-7-9 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 211226
DEA: 024E6404
EFIS: 0212000011
DIST-CO-RTE-PM02-PLU-147-8.9/9.3
Work DescriptionREPLACE BRIDGE, GUARDRAILING, HMA, STRIPING
Location DescriptionPLUMAS COUNTY ABOUT 9 MILES NORTH OF CANYON DAM FROM 0.1 MILE SOUTH TO 0.4 MILE NORTH OF HAMILTON BRANCH BRIDGE
Sample Information
Sample Taken Date3/23/2017 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing3/27/2017
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes12 From where was the sample collectedFabricator
First name of sampler or witnessed byG Last name of sampler or witnessed byJohnston
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameCMC Rebar Transportation Laboratory (TL) NumberC953696
Inspector Lot Number from the Transportation Laboratory (TL) FormL5306417 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)6502634303
Hoop Manufacturer Lot Number(s)1, 5, 7 Material Standard CodeASTM A706
Material Grade60 Rebar Size6
Diameter of Hoop2'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded
Test Details
DIME Sample ID: 2017-03-23-7
DIME Test ID: 2017-03-23-7-9
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-04-05
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 03/28/2017
UTM:400KIP
Temperature:72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
137#6/19mm0.444131093890Bar BrokeBrian

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 03/29/2017