Summary for Test 2017-02-21-8-1
Test performed: ASTM A370-15Project Information
Project Identifiers | Project ID: 8196 DEA: 59912684 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | |
Location Description | |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 02/21/2017 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/22/2017 |
Sample type | Retest | A brief description of the sample | A536 Ductile Iron |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Justin | Last name of sampler or witnessed by | Ice |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | SDI Farrar | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM6 - Ductile Iron Cast Samples | Heat Number (s) | B237 |
---|---|---|---|
Part Number (s) | SDI 22 6 PC | Material Specification | A536 |
Grades | 80-55-06 | Metal Foundry Manufacturer (Mill) | Farrar |
Prestressing Manufacturer | SDI |
Test Details
DIME Sample ID: 2017-02-21-8
DIME Test ID: 2017-02-21-8-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2017-03-31
Test Results
Number of Samples: 2
Input Type: Calculated
Tester's full name: Fred
Date of test: 03/23/2017
UTM: 67KIP
Temperature: 72 F
Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | B237 | 0.496 | 0.1932 | 59886 | 102230 | 8.6 | Fred | |
2 | B237 | 0.496 | 0.1932 | 60705 | 103470 | 8.6 | Fred |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Test was verified on 3/24/2017 ✔