Summary for Test 2017-03-01-6-6

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 3807
DEA: 07121844
EFIS: 0700000117
DIST-CO-RTE-PM07-LA-5-42.8/47.3
Award Date12/06/2010
Closeout Date06/30/2021
Work DescriptionCONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 02/23/2012)

Sample Information

Sample Taken Date03/01/2017 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/20/2017
Sample typeQuality Assurance A brief description of the sampleBarsplice Double Barrel Zap Screwlok
The quantity of what the sample constitutes20 From where was the sample collectedJob Site
First name of sampler or witnessed byJayoen Last name of sampler or witnessed byYoung
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameGerdau BarSplce Transportation Laboratory (TL) NumberC686077
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerBarsplice Intermediate Assembler or FabricatorUnknown
Rebar Size#5/6 Coupler ModelBarsplice Double Barrel Zap Screwlok
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)11200, 01031 Rebar Heat Number(s)65025732, 65025580
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2017-03-01-6
DIME Test ID: 2017-03-01-6-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-03-29

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 03/22/2017
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
132#5/16mm , 6/19mm, Trans 0.312991096480Service SpliceFred

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 3/22/2017