Summary for Test 2017-03-06-11-1

Test performed: CONCLP 4-16

Project Information

Project IdentifiersProject ID: 211736
DEA: 042A4904
EFIS: 0400000827
DIST-CO-RTE-PM04-SF-280-R4.8/R6.2
Award Date12/09/2016
Closeout Date01/30/2018
Work DescriptionBRIDGE POLYESTER CONCRETE OVERLAY, DRAINAGE AND BARRIER RECONSTRUCTION
Location DescriptionTHE CITY AND COUNTY OF SAN FRANCISCO AT VARIOUS LOCATIONS FROM 0.5 MILE NORTH OF ROUTE 280/101 SEPARATION TO 0.2 MILE SOUTH OF 20TH STREET OVERCROSSING
QA Service Level1 (Verified on 01/31/2017)

Sample Information

Sample Taken Date03/06/2017 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/08/2017
Sample typeQuality Control A brief description of the sample1 gallon can
The quantity of what the sample constitutes80 drums and 16 totes From where was the sample collectedSource
First name of sampler or witnessed byChris Last name of sampler or witnessed byNunes
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility namekwik Bond, Benecia Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeMethacrylate Mfg. Lot Number(s)17-20-189288
Batch number1720189288 Mix number3229

Test Details

DIME Sample ID: 2017-03-06-11
DIME Test ID: 2017-03-06-11-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2017-03-21

Test Results


Input Type: Calculated
Tester's full name: Mike Mullins
Date of test: 03/21/2017
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 21.25 cps
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 1.089
Volatile content (ASTM D 2369) 30% max: 24.63 %
Flash point (ASTM D 3828) more than 180 deg F: 210 F
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 690 psi
Tack free time, 400 minutes max: 240 minutes
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/21/2017