Summary for Test 2017-02-15-2-1
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 211997 DEA: 044K1504 EFIS: 0417000271 COOP: 250 |
---|---|
DIST-CO-RTE-PM | 04-MRN-1-4.0/8.0, 4.0/5.0 |
Award Date | 01/03/2017 |
Closeout Date | 12/20/2017 |
Work Description | const SPW and replace culvert |
Location Description | Not set |
QA Service Level | 1 (Verified on 02/03/2017) |
Sample Information
Sample Taken Date | 02/15/2017 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/27/2017 |
Sample type | Quality Assurance | A brief description of the sample | Concrete Cylinder 6 x 12 |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | janine | Last name of sampler or witnessed by | Marr |
Title of sampler | SR | Telephone number of sampler | 5103856764 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Shamrock | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Solder PIle wall |
Material Information
Material Type | Concrete | The concrete mix design number | 4201A |
---|---|---|---|
The truck number from where the sample was collected | 1215 | The batch plant ticket number from where the sample was collected | 151247 |
Concrete batch plant | 1 | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | Chute | Where the material sample would have been placed if not sampled | Concrete Backfill for Soldier Pile |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2017-02-15-2
DIME Test ID: 2017-02-15-2-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2017-03-15
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Bang
Date of test: 03/15/2017
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.96 in
Maximum load on cylinder 1: 145689 lb
Maximum load on cylinder 2: 145002 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 27.9 in^2
Compressive strength of cylinder 1: 5186.5 psi
Compressive strength of cylinder 2: 5197.2 psi
Compressive strength (to nearest 10 psi): 5190 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 2
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2
Test was verified on 3/15/2017 ✔