Test 2017-02-10-13-1 (ASTM C39-17a) Summary

Project Information
Project IdentifiersProject ID: 210569
DEA: 083555V4
EFIS: 0814000086
DIST-CO-RTE-PM08-SBD-15-42.5/46.0
Work DescriptionWIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR.
Location DescriptionSAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING
Sample Information
Sample Taken Date2/10/2017 Sample Unique Key13
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing2/15/2017
Sample typeQuality Control A brief description of the sample6x12
The quantity of what the sample constitutes2 From where was the sample collectedJob Site
First name of sampler or witnessed byDARREN Last name of sampler or witnessed byHOPPER
Title of samplerASR Laboratory sample identification934-11
The fabricator/manufacturer/facility nameROBERSTSONS Transportation Laboratory (TL) Number180611
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierVICTORVILLE SEP AND OH BR WIDEN
Structure nameBENT 4 LEFT PIER WALL
Material Information
Material TypeConcrete The concrete mix design numberSC675B38
The truck number from where the sample was collected1694 The batch plant ticket number from where the sample was collected2381663
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedPUMP TREMIE Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown
Test Details
DIME Sample ID: 2017-02-10-13
DIME Test ID: 2017-02-10-13-1
Testing Lab: CT - Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2017-03-10
Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 03/10/2017
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 153530 lb
Maximum load on cylinder 2: 154840 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 5430.8 psi
Compressive strength of cylinder 2: 5477.2 psi
Compressive strength (to nearest 10 psi):5450 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 03/10/2017