Test 2017-02-09-5-3 (SMTL CHEM-16) Summary

Project Information
Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
Sample Information
Sample Taken Date2/9/2017 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing2/17/2017
Sample typeQuality Assurance A brief description of the sampleA709 Steel Check Sample
The quantity of what the sample constitutes1 From where was the sample collectedFabricator
First name of sampler or witnessed byJoe Last name of sampler or witnessed byLanz
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameStinger Bridge Iron Transportation Laboratory (TL) NumberC952663
Inspector Lot Number from the Transportation Laboratory (TL) FormL10600517 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM6 - Steel Check Sample Plate Heat Number(s)U8199
Material SpecificationA709 GradeHPS 50W
Thickness3.25 ShapeSquare
Metal Foundry Manufacturer (Mill)Arcelormittal Plate Plate Dimension12 x 12
Test Details
DIME Sample ID: 2017-02-09-5
DIME Test ID: 2017-02-09-5-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: SMTL CHEM-16: Steel Chemistry Analysis
Test Release Date: 2017-03-08
Test Results

Input Type: Measured
Tester's full name: Glen Weldon
Date of test: 02/27/2017
Result:Pass
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 03/01/2017