Summary for Test 2017-02-16-10-3

Test performed: ASTM A970-15e1

Project Information

Project IdentifiersProject ID: 210735
DEA: 071193U4
EFIS: 0713000007
DIST-CO-RTE-PM07-LA-10-37.2/42.4
Award Date11/16/2015
Closeout Date07/11/2022
Work DescriptionCONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS.
Location DescriptionIN LA COUNTY FROM CITRUS STREET IN WEST COVINA TO ROUTE 57 IN POMONA
QA Service Level1 (Verified on 03/07/2016)

Sample Information

Sample Taken Date02/16/2017 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/17/2017
Sample typeQuality Assurance A brief description of the sampleHRC 110 End Anchors
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byGreg Last name of sampler or witnessed byJohnston
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHRC CMC Rebar Transportation Laboratory (TL) NumberC953682
Inspector Lot Number from the Transportation Laboratory (TL) FormL5302717 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)4062633 Head Manufacturer Lot Number(s)3
Rebar Size#5 Headed Bar Model NameHRC 110
Size of HeadReduced Size - 4x Head Connection TypeInertia Weld
Head ShapeRectanglar Rebar ManufacturerCMC Rebar
Head ManufacturerHRC Head FabricatorHRC
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Test Details

DIME Sample ID: 2017-02-16-10
DIME Test ID: 2017-02-16-10-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2017-03-01

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 02/21/2017
UTM: 400KIP
Temperature: 72 F
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
130.312959095450Head Popped OffBrian

General comments (publicly viewable) (Max 1000 characters): Head Popped Off
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 2/22/2017