Summary for Test 2017-02-08-5-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Award Date09/02/2011
Closeout DateNot set
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
QA Service Level1 (Verified on 06/03/2013)

Sample Information

Sample Taken Date02/08/2017 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/13/2017
Sample typeQuality Assurance A brief description of the sample Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byB Last name of sampler or witnessed byNou
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHRC Transportation Laboratory (TL) NumberC952624
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Gerdau
Coupler ManufacturerHRC Nucor Intermediate Assembler or FabricatorUnknown
Rebar Size18 Coupler ModelHRC 410/490
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorHRC
Coupler Component Heat/Lot Number(s)NF15102411, NF16203564 Rebar Heat Number(s)3058432, 6502035104, 3058431
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2017-02-08-5
DIME Test ID: 2017-02-08-5-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2017-02-21

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 02/14/2017
UTM: 2000KIP
Halo ID: Big
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1263#18/57mm4037974994937necking okayBrian

General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
WARNING: No graph data imported from Instron machine.

Test was verified on 2/14/2017