Summary for Test 2017-02-08-1-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 210808
DEA: 020E0904
EFIS: 0200000016
DIST-CO-RTE-PM02-SHA-5-R29.3/R31.1,R45.0/R45.8
Award Date02/03/2016
Closeout Date10/21/2020
Work DescriptionREPLACE BRIDGE, REALIGN ROADWAY AND SEISMIC RETROFIT
Location DescriptionIN SHASTA COUNTY ABT 8 MI N OF SHASTA LAKE CTY AND NEAR LAKEHEAD FRM TURNTABLE BAY O/C TO 0.1 MI N OF O'BRIEN SRRA & FRM 0.4 MI S TO 0.3 MI N OF DOG CREEK BRIDGE.
QA Service Level1 (Verified on 09/23/2015)

Sample Information

Sample Taken Date02/08/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/08/2017
Sample typeQuality Assurance A brief description of the sampleStainless Steel
The quantity of what the sample constitutes2 From where was the sample collectedFabricator
First name of sampler or witnessed byCorey Last name of sampler or witnessed byGardner
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameContractor Materials Company Transportation Laboratory (TL) NumberC704031
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNorth American Stainless
Coupler ManufacturerNorth American Stainless Intermediate Assembler or FabricatorUnknown
Rebar Size#8 Coupler ModelThreaded stainless Coupler
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)M9P1 Rebar Heat Number(s)Y1E0
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2017-02-08-1
DIME Test ID: 2017-02-08-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2017-03-01

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 02/10/2017
UTM: 400KIP
Temperature: 72 F
Halo ID: Small
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1210000#8/25mm Stainless steel100.7982911104950Pull out of couplerFred

General comments (publicly viewable) (Max 1000 characters): Pull out of coupler
Test Graph
Source: Partner Data Point File

Test was verified on 2/22/2017