Test 2017-01-31-6-1 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 210735
DEA: 071193U4
EFIS: 0713000007
DIST-CO-RTE-PM07-LA-10-37.2/42.4
Work DescriptionCONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS.
Location DescriptionIN LA COUNTY FROM CITRUS STREET IN WEST COVINA TO ROUTE 57 IN POMONA
Sample Information
Sample Taken Date1/31/2017 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing2/8/2017
Sample typeQuality Assurance A brief description of the sampleDayton Bar lock couplers
The quantity of what the sample constitutes8 From where was the sample collectedJob Site
First name of sampler or witnessed byGlenn Last name of sampler or witnessed byStoeker
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameCMC Rebar Dayton Superior Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormN/A Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size#10, 11 Coupler ModelBar-Lock
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)490608, 74099703, 492018 Rebar Heat Number(s)4063141, 4061949
Rebar Size 2 Not set
Test Details
DIME Sample ID: 2017-01-31-6
DIME Test ID: 2017-01-31-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2017-03-02
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 02/09/2017
UTM: 2000KIP
Halo ID: Big
Temperature:72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111#10/32mm1.27-0.001711222088362Service SpliceFred

General comments (publicly viewable) (Max 250 characters): Service Splice
Test Graph
WARNING: No graph data imported from Instron machine.

Test was verified on 02/23/2017