Summary for Test 2017-01-16-4-6

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211366
DEA: 051G4604
EFIS: 0515000032
DIST-CO-RTE-PM05-SLO-101-R24.3
Award Date06/13/2016
Closeout Date02/01/2018
Work DescriptionREPLACE EXISTING BRIDGE RAIL, COLD PLANE AND RESURFACE PAVEMENT.
Location DescriptionSAN LUIS OBISPO COUNTY NEAR SAN LUIS OBISPO AT SANTA FE UNDERCROSSING
QA Service Level1 (Verified on 07/27/2016)

Sample Information

Sample Taken Date01/16/2017 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/31/2017
Sample typeQuality Assurance A brief description of the sampleBarsplice Doublr Barrel Zap Screwlok Coupler
The quantity of what the sample constitutes8 From where was the sample collectedJob Site
First name of sampler or witnessed bySalvador Last name of sampler or witnessed byHeredia
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameBarsplice, Nucor Transportation Laboratory (TL) NumberC918904 C918909
Inspector Lot Number from the Transportation Laboratory (TL) FormN/A Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerBarsplice Intermediate Assembler or FabricatorUnknown
Rebar Size#5 Coupler ModelDoublr Barrel Zap Screwlok Coupler
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)5328 Rebar Heat Number(s)SE1510034801
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2017-01-16-4
DIME Test ID: 2017-01-16-4-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-02-07

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 01/31/2017
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
136#5/16mm0.312900093550Service SpliceFred

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 1/31/2017