Summary for Test 2013-10-16-9003619-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 5266
DEA: 08448404
EFIS: 0800000712
COOP: 081488A1
DIST-CO-RTE-PM08-RIV-91-15.6/21.6
Award Date02/10/2012
Closeout Date07/27/2023
Work DescriptionCONSTRUCT HOV LANES AND WIDEN BRIDGES.
Location DescriptionRIVERSIDE COUNTY IN RIVERSIDE FROM ADAMS STREET TO THE ROUTE 60/215 SEPARATION
QA Service Level1 (Verified on 04/27/2012)

Sample Information

Sample Taken Date10/16/2013 Sample Unique Key9003619
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/16/2013
Sample typeAcceptance A brief description of the sampleClass 2 Aggregate Subbase
The quantity of what the sample constitutes1 Bag From where was the sample collectedOther
First name of sampler or witnessed byKohnson Last name of sampler or witnessed byChan
Title of samplerTE Telephone number of samplerNot set
Laboratory sample identificationNot set Linked DIME Sample IDNot set
The fabricator/manufacturer/facility nameE/B 91 Sta 338 00 Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Unknown
The fabricator's/manufacturer's product name for the sampleClass 2 Aggregate Subbase The fabricator/manufacturer designation for the sampleNot set
The plant numberNot set A detailed description of where the material sample was collectedE/B 91 Sta. 338 00
Where the material sample would have been placed if not sampledNot set Primary Aggregate Nominal Size
The concrete mix design number Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2013-10-16-9003619
DIME Test ID: 2013-10-16-9003619-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2015-02-20

Test Results


Number of tests: 1
Input Type: Calculated
Tester's full name: Nemencio Daof
Date of test: 10/17/2013
Temperature correction: no data
Temperature of solution: no data
Clay reading (test 1): no data
Sand reading (test 1): no data
Sand equivalent (test 1): no data
Sand equivalent before temperature correction: no data
Sand equivalent after temperature correction: 28
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/20/2015