Summary for Test 2017-01-06-2-2
Test performed: CONCLP 4-16Project Information
Project Identifiers | Project ID: 211603 DEA: 11417804 EFIS: 1114000039 |
---|---|
DIST-CO-RTE-PM | 11-SD-8,15,52,56,67,76,78,805-Various |
Award Date | 09/26/2016 |
Closeout Date | 09/10/2018 |
Work Description | CLEAN AND TREAT BRIDGE DECK WITH METHACRYLATE, REPLACE JOINT SEALS. |
Location Description | SAN DIEGO COUNTY AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 11/15/2016) |
Sample Information
Sample Taken Date | 01/06/2017 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/09/2017 |
Sample type | Quality Control | A brief description of the sample | HMWM |
The quantity of what the sample constitutes | 25000 gal | From where was the sample collected | Source |
First name of sampler or witnessed by | Chris | Last name of sampler or witnessed by | Nunes |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | kwik Bond, Benecia | Transportation Laboratory (TL) Number | C594914 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Methacrylate | Mfg. Lot Number(s) | 17-10-089188 |
---|---|---|---|
Batch number | 1710089188 | Mix number | 3219 |
Test Details
DIME Sample ID: 2017-01-06-2
DIME Test ID: 2017-01-06-2-2
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2017-01-12
Test Results
Input Type: Calculated
Tester's full name: Mike Mullins
Date of test: 01/12/2017
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 19 cps
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 1.09
Volatile content (ASTM D 2369) 30% max: 24.7 %
Flash point (ASTM D 3828) more than 180 deg F: 214 F
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 650 psi
Tack free time, 400 minutes max: 240 minutes
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/12/2017 ✔