Test 2013-11-12-11009128-1 (ASTM C136-06) Summary

Project Information
Project IdentifiersProject ID: 7780
DEA: 112T1824
EFIS: 1100020051
DIST-CO-RTE-PM11-SD-805-4.7/5.6
Work DescriptionREPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR).
Location DescriptionSAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING
Sample Information
Sample Taken Date11/12/2013 Sample Unique Key11009128
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/12/2013
Sample typeQuality Control A brief description of the samplePortland Cement Concrete Aggregates
The quantity of what the sample constitutes2 bags From where was the sample collectedSource
First name of sampler or witnessed byMike Last name of sampler or witnessed bynatisin
Title of samplerNot set Laboratory sample identificationNot set
The fabricator/manufacturer/facility nameVulcan Mission Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-37-0035
The fabricator's/manufacturer's product name for the sampleNot set The fabricator/manufacturer designation for the sampleNot set
The plant numberNot set A detailed description of where the material sample was collectedconveyor belt
Where the material sample would have been placed if not sampledNot set Primary Aggregate Nominal Size
The concrete mix design number Lot numberNot set
Sublot numberNot set HMA Design ID
Test Details
DIME Sample ID: 2013-11-12-11009128
DIME Test ID: 2013-11-12-11009128-1
Testing Lab: Vulcan Materials Company - San Diego
Test Method: ASTM C136-06: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2013-11-13
Test Results

What type of gradation is being tested?: 1 in. x No. 4 - Coarse Aggregate
Input Type: Calculated
Tester's full name: mike natisin
Date of test: 11/12/2013
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:99 %
Cumulative percent passing the 3/4 in. sieve:88 %
Cumulative percent passing the 1/2 in. sieve:43 %
Cumulative percent passing the 3/8 in. sieve:21 %
Cumulative percent passing the #4 sieve:6 %
Cumulative percent passing the #8 sieve:1 %
General comments (publicly viewable) (Max 250 characters):

Test was verified on 11/13/2013