Summary for Test 2016-12-08-4-3

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 209217
DEA: 080F5404
EFIS: 0800000136
COOP: 081468
DIST-CO-RTE-PM08-RIV-91,15-0.0/13.04, 35.64/45.14
Award Date09/09/2013
Closeout Date09/20/2023
Work DescriptionSR-91 Corridor Improvement Project: Develop approx. 8 miles of tolled express lanes and related improvements within SR 91 between the Riverside/Orange County line and I-15, including transition areas.
Location Description08-RIV-91-0.0/13.04; 12-ORA-91-R14.43/R18.91; 08-RIV-15-35.64/45.14
QA Service Level1 (Verified on 08/07/2014)

Sample Information

Sample Taken Date12/08/2016 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/13/2016
Sample typeQuality Assurance A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes6 From where was the sample collectedJob Site
First name of sampler or witnessed byJOSE Last name of sampler or witnessed byDIAZ
Title of samplerTET Telephone number of samplerUnknown
Laboratory sample identification888-SRL380 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHolliday Rock Chino Transportation Laboratory (TL) NumberSRL380
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNP
Structure name91 CIP

Material Information

Material TypeConcrete The concrete mix design numberCM5636
The truck number from where the sample was collected280 The batch plant ticket number from where the sample was collected101091029
Concrete batch plantNP The fabricator/manufacturer designation for the sampleNP
A detailed description of where the material sample was collectedLOAD 7 Where the material sample would have been placed if not sampledBR 30 DECK
From Lot No.NP Bag Lot No.Unknown

Test Details

DIME Sample ID: 2016-12-08-4
DIME Test ID: 2016-12-08-4-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2017-01-05

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 01/05/2017
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 153800 lb
Maximum load on cylinder 2: 150330 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 5440.4 psi
Compressive strength of cylinder 2: 5317.7 psi
Compressive strength (to nearest 10 psi): 5380 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/5/2017