Test 2016-12-30-1-3 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 210808
DEA: 020E0904
EFIS: 0200000016
DIST-CO-RTE-PM02-SHA-5-R29.3/R31.1,R45.0/R45.8
Work DescriptionREPLACE BRIDGE, REALIGN ROADWAY AND SEISMIC RETROFIT
Location DescriptionIN SHASTA COUNTY ABT 8 MI N OF SHASTA LAKE CTY AND NEAR LAKEHEAD FRM TURNTABLE BAY O/C TO 0.1 MI N OF O'BRIEN SRRA & FRM 0.4 MI S TO 0.3 MI N OF DOG CREEK BRIDGE.
Sample Information
Sample Taken Date12/30/2016 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing1/4/2017
Sample typeQuality Assurance A brief description of the sampleHRC 500 510 Couplers
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byBob Last name of sampler or witnessed byThompson
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameHarris Rebar HRC Nucor Transportation Laboratory (TL) NumberC691785
Inspector Lot Number from the Transportation Laboratory (TL) FormN/A Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerHRC Intermediate Assembler or FabricatorUnknown
Rebar Size#14 Coupler Model500 510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)0K1753, MM15103267 Rebar Heat Number(s)SE14105871
Rebar Size 2 Not set
Test Details
DIME Sample ID: 2016-12-30-1
DIME Test ID: 2016-12-30-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2017-01-12
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 01/04/2017
UTM: 2000KIP
Halo ID: Big
Temperature:72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
13C01#14/43mm2.25021833997040necking okayFred

General comments (publicly viewable) (Max 250 characters): necking okay
Test Graph
WARNING: No graph data imported from Instron machine.

Test was verified on 01/05/2017