Summary for Test 2016-12-16-5-2

Test performed: ASTM A722-15

Project Information

Project IdentifiersProject ID: 3825
DEA: 07138204
EFIS: 0700000142
DIST-CO-RTE-PM07-LA-47,103-3.5/4.6,0.0/1.1
Award Date06/30/2011
Closeout Date07/14/2022
Work DescriptionREPLACE STEEL BRIDGE WITH CIP PS CONCRETE BOX GIRDER BRIDGE AND RAMPS.
Location DescriptionLOS ANGELES COUNTY IN LONG BEACH AND LOS ANGELES ON ROUTE 47 FROM OCEAN BOULEVARD TO ROUTE 103 JUNCTION AND ON ROUTE 103 FROM ROUTE 47 JUNCTION TO ANAHEIM STREET OVERHEAD
QA Service Level1 (Verified on 03/29/2012)

Sample Information

Sample Taken Date12/16/2016 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/19/2016
Sample typeQuality Assurance A brief description of the sampleA722 Threaded Bar
The quantity of what the sample constitutes2 From where was the sample collectedDistributor
First name of sampler or witnessed byGreg Last name of sampler or witnessed byJohnston
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameDSI Transportation Laboratory (TL) NumberC731320
Inspector Lot Number from the Transportation Laboratory (TL) FormL5304916 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A722 Threaded Bar Grade150
Threaded Bar TypeDeformed Rebar Size14
Nut Specification for Threaded BarNA System ManufacturerDSI
Epoxy Coating ColorNA Threaded Bar ApplicationThreaded Bar
Coating StandardsUncoated Bar Heat Number(s)62142159
Nut Heat Number(s)N/A Bar Lot NumberUnknown
Nut Lot NumberNA Coupler Heat Number(s)73101134
Coupler GradeUnknown

Test Details

DIME Sample ID: 2016-12-16-5
DIME Test ID: 2016-12-16-5-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2017-01-10

Test Results


Number of Threaded Bar Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 01/03/2017
UTM: 2000KIP
Temperature: 72 F
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
12A722 DSI 1.750 Threaded Bar, CouplerBar Heat #62142159, Coupler Heat #731011342.5816581014767000DSI Threaded Bar & CouplerFred

General comments (publicly viewable) (Max 1000 characters): DSI Threaded Bar & Coupler
Test Graph
WARNING: No graph data imported from Instron machine.

Test was verified on 1/3/2017