Summary for Test 2016-12-05-3-5

Test performed: ASTM A934-13

Project Information

Project IdentifiersProject ID: 210951
DEA: 120M3404
EFIS: 1212000017
DIST-CO-RTE-PM12-ORA-73,133-16.6,4.2
Award Date03/29/2016
Closeout Date06/17/2021
Work DescriptionWIDEN RAMP, CONSTRUCT RW AND DI, AND MODIFY LIGHTING
Location DescriptionNot set
QA Service Level1 (Verified on 03/30/2016)

Sample Information

Sample Taken Date12/05/2016 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/07/2016
Sample typeQuality Assurance A brief description of the sampleWilliams Thread Bars
The quantity of what the sample constitutes4 From where was the sample collectedManufacturer
First name of sampler or witnessed byKen Last name of sampler or witnessed byVarela
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameWilliams Form Transportation Laboratory (TL) NumberC939307
Inspector Lot Number from the Transportation Laboratory (TL) FormL0814016 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade75
Threaded Bar Type Rebar Size#8
Nut Specification for Threaded BarAISI 1045 System ManufacturerWilliams Form
Epoxy Coating ColorPurple Threaded Bar ApplicationThreaded Bar
Coating StandardsASTM A934 epoxy Bar Heat Number(s)NF16202580, NF16102113
Nut Heat Number(s)NF15202140 Bar Lot NumberUnknown
Nut Lot Number8P5D Coupler Heat Number(s)
Coupler Grade

Test Details

DIME Sample ID: 2016-12-05-3
DIME Test ID: 2016-12-05-3-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Test Release Date: 2016-12-19

Test Results


Input Type: Measured
Tester's full name: Glen Weldon
Date of test: 12/08/2016
Lower spec. limit LSL: 10 mils
Upper spec. limit USL: 15 mils
Bar # for First Bar: B1
Bar # for Second Bar: B2
First Bar Side 1 mean value: 12.29 mils
First Bar Side 2 mean value: 13.42 mils
Second Bar Side 1 mean value: 7.404 mils
Second Bar Side 2 mean value: 7.432 mils
First Bar Mean: 12.86 mils
Second Bar Mean: 7.42 mils
Total mean value: 10.14 mils
General comments (publicly viewable) (Max 1000 characters): Heat #NF16102113 Fails - 5 Readings below 80% of 10 mil minimum coating thickness.

Test was verified on 12/12/2016