Summary for Test 2016-11-17-6-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 210696
DEA: 080M2804
EFIS: 0800000472
DIST-CO-RTE-PM08-SBD-15-171.8/173.8
Award Date11/04/2015
Closeout Date08/21/2018
Work DescriptionBRIDGE REPLACEMENT AND WIDEN, CONC AND HMA PVMT, COLD PLANE AC PVMT.
Location DescriptionIn SBD County
QA Service Level1 (Verified on 10/19/2015)

Sample Information

Sample Taken Date11/17/2016 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/21/2016
Sample typeQuality Assurance A brief description of the sampleLenton Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byFaisal Last name of sampler or witnessed byZahlout
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameGerdau Erico Transportation Laboratory (TL) NumberC010
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerErico Intermediate Assembler or FabricatorUnknown
Rebar Size10 Coupler ModelLenton
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)LA424 Rebar Heat Number(s)6502452802
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2016-11-17-6
DIME Test ID: 2016-11-17-6-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2016-11-22

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 11/22/2016
UTM: 2000KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12NA#10/32mm1.27012062994983necking okayBrian

General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
WARNING: No graph data imported from Instron machine.

Test was verified on 11/22/2016