Summary for Test 2016-09-09-11-5

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 210859
DEA: 010B3104
EFIS: 0112000115
DIST-CO-RTE-PM01-DN-199-8.7,21.7
Award Date01/04/2016
Closeout Date02/16/2017
Work DescriptionCONSTRUCT BUTTRESSES
Location DescriptionIN DEL NORTE COUNTY NEAR GASQUET AT1.6 MILES NORTH OF MYRTLE CREEK BRIDGE AND ABOUT 8 MILES NORTH OF GASQUET AT 0.4 MILE SOUTH OF PATRICK CREEK BRIDGE
QA Service Level1 (Verified on 09/23/2015)

Sample Information

Sample Taken Date09/09/2016 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/17/2016
Sample typeQuality Assurance A brief description of the sampleBarlock couplers
The quantity of what the sample constitutes8 From where was the sample collectedJob Site
First name of sampler or witnessed byNA Last name of sampler or witnessed byNA
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameNA Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCascade
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size5 & 6 Coupler ModelBarlock
Coating StandardsASTM A934 Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)5L-127220, 6L-133375 Rebar Heat Number(s)212416, 167616
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2016-09-09-11
DIME Test ID: 2016-09-09-11-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2016-11-17

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 11/17/2016
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
122#6/19mm0.4404256696741Service SpliceFred

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 11/17/2016