Summary for Test 2016-11-10-5-1
Test performed: ASTM A370-15Project Information
Project Identifiers | Project ID: 210696 DEA: 080M2804 EFIS: 0800000472 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-171.8/173.8 |
Award Date | 11/04/2015 |
Closeout Date | 08/21/2018 |
Work Description | BRIDGE REPLACEMENT AND WIDEN, CONC AND HMA PVMT, COLD PLANE AC PVMT. |
Location Description | In SBD County |
QA Service Level | 1 (Verified on 10/19/2015) |
Sample Information
Sample Taken Date | 11/10/2016 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/14/2016 |
Sample type | Quality Assurance | A brief description of the sample | Coupon Casting |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Debbie | Last name of sampler or witnessed by | Ozuna |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Manchester Metals | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM6 - Ductile Iron Cast Samples | Heat Number (s) | 27J16, 28J16 |
---|---|---|---|
Part Number (s) | 68 19 246 | Material Specification | A536 |
Grades | 65-45-12 | Metal Foundry Manufacturer (Mill) | Manchester Metals |
Prestressing Manufacturer | DSI |
Test Details
DIME Sample ID: 2016-11-10-5
DIME Test ID: 2016-11-10-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2016-11-18
Test Results
Number of Samples: 2
Input Type: Calculated
Tester's full name: Arnold
Date of test: 11/16/2016
UTM: 67KIP
Temperature: 72 F
Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 27J16 | 0.499 | 0.1956 | 49700 | 86930 | 14.2 | Arnold | |
2 | 28J16 | 0.499 | 0.1956 | 49613 | 83800 | 13.3 | Arnold |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Test was verified on 11/18/2016 ✔