Summary for Test 2016-11-07-3-4
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 211391 DEA: 074T7104 EFIS: 0714000209 |
---|---|
DIST-CO-RTE-PM | 07-LA-66-2.9 |
Award Date | 06/17/2016 |
Closeout Date | 07/05/2017 |
Work Description | INSTALL TRAFFIC AND PEDESTRIAN SIGNALS. |
Location Description | LOS ANGELES COUNTY IN POMONA AT SUMNER AVENUE |
QA Service Level | 1 (Verified on 06/06/2016) |
Sample Information
Sample Taken Date | 11/07/2016 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/10/2016 |
Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar Hoops |
The quantity of what the sample constitutes | 12 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Gary | Last name of sampler or witnessed by | MaComb |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | TNT Rebar Nucor Cascade | Transportation Laboratory (TL) Number | C970389 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L1013016 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | PL16201954, 001916 |
Hoop Manufacturer Lot Number(s) | 1 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | #4,5,5 |
Diameter of Hoop | 2'-2", 2'-8", 3'-2" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Nucor Cascade |
Welding Company | TNT Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2016-11-07-3
DIME Test ID: 2016-11-07-3-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-11-16
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 11/16/2016
UTM: 400KIP
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | 2 3\'-2\" | #5/16mm | 0.31 | 29290 | 94480 | Bar Broke in Heat Affected Area | Fred |
General comments (publicly viewable) (Max 1000 characters): Bar Broke in Heat Affected Area; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 11/16/2016 ✔