Summary for Test 2016-09-28-18-5
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 209918 DEA: 07274804 EFIS: 0700000516 |
---|---|
DIST-CO-RTE-PM | 07-LA-18-0.2 |
Award Date | 12/09/2014 |
Closeout Date | 01/15/2018 |
Work Description | REPLACE BRIDGE DECK AND RAILING, REPAIR BENT CAPS AND COLUMNS. |
Location Description | LOS ANGELES COUNTY AT LLANO AT COUNTY LINE OVERHEAD |
QA Service Level | 1 (Verified on 01/08/2015) |
Sample Information
Sample Taken Date | 09/28/2016 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/30/2016 |
Sample type | Quality Assurance | A brief description of the sample | Concrete 6 x 12 Cylinders |
The quantity of what the sample constitutes | 10 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | A | Last name of sampler or witnessed by | AMBAYE |
Title of sampler | ASR | Telephone number of sampler | Unknown |
Laboratory sample identification | 936-A1 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | HI GRADE MATERIALS | Transportation Laboratory (TL) Number | 786-A1 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | SITI72A2 |
---|---|---|---|
The truck number from where the sample was collected | 185 | The batch plant ticket number from where the sample was collected | 1 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | TRUCK | Where the material sample would have been placed if not sampled | BRIDGE DECK REPLACEMENT LIANO CALIFORNIA |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2016-09-28-18
DIME Test ID: 2016-09-28-18-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-11-09
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 11/09/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 163150 lb
Maximum load on cylinder 2: 160190 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 42 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 5732.6 psi
Compressive strength of cylinder 2: 5628.6 psi
Compressive strength (to nearest 10 psi): 5680 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/9/2016 ✔