Test 2016-10-28-4-2 (ASTM A884-13) Summary

Project Information
Project IdentifiersProject ID: 8196
DEA: 59912684
DIST-CO-RTE-PM59---
Work Description
Location Description
Sample Information
Sample Taken Date10/28/2016 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/2/2016
Sample typeQuality Assurance A brief description of the sampleGreen Epoxy Dowels
The quantity of what the sample constitutes2 From where was the sample collectedFabricator
First name of sampler or witnessed byRob Last name of sampler or witnessed byRAMOS
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameDayton Superior Transportation Laboratory (TL) NumberC875577
Inspector Lot Number from the Transportation Laboratory (TL) FormS0804016 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM7 - Epoxy Coated Dowels Dowel Metal Heat NumberSE16103106
Dowel Epoxy Batch NumberUnknown Dowel Coating SpecificationASTM A775
Dowel Size1.5 in Dowel Coating ColorGreen
Dowel ManufacturerUnknown Dowel CoaterDayton Superior
Release Number10-28-16-1-1 Quality Assurance CodeUnknown
Rebar Size (#)
Test Details
DIME Sample ID: 2016-10-28-4
DIME Test ID: 2016-10-28-4-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A884-13: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)
Test Release Date: 2016-11-02
Test Results

Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 11/02/2016
Total Number of Holiday: 0
Total Length: 3 ft
Holidays Per Linear Foot of Bar:0 holiday per ft
Holiday Test Pass/Fail:Pass
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/02/2016