Summary for Test 2016-10-14-5-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 210804 DEA: 11413704 EFIS: 1114000112 |
---|---|
DIST-CO-RTE-PM | 11-IMP-8-R65.0/R74.5 |
Award Date | 12/15/2015 |
Closeout Date | 08/31/2018 |
Work Description | CONSTRUCT CRCP, HMA-A, GUARDRAIL, AND RUMBLE STRIPS. |
Location Description | IN IMPERIAL COUNTY ABOUT 26 MILES EAST OF EL CENTRO FROM 0.8 MILE WEST OF EAST JUNCTION ROUTE 98/ ROUTE 8 SEPARATION TO 0.6 MILE EAST OF ALL AMERICAN CANAL. |
QA Service Level | 1 (Verified on 04/01/2016) |
Sample Information
Sample Taken Date | 10/14/2016 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/18/2016 |
Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar Hoops |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Tory | Last name of sampler or witnessed by | Mclaurin |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | TNT Rebar Cascade | Transportation Laboratory (TL) Number | C730523 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L6729116 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 043916 |
Hoop Manufacturer Lot Number(s) | 1 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 4 |
Diameter of Hoop | 2'-2" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Cascade |
Welding Company | TNT Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2016-10-14-5
DIME Test ID: 2016-10-14-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-10-19
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 10/19/2016
UTM: 75KIP
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | 1 | #4/13mm | 0.2 | 18466 | 92330 | necking okay | Fred |
General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
WARNING: No graph data imported from Instron machine.
Test was verified on 10/19/2016 ✔