Summary for Test 2016-10-04-11-6

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211562
Permit Numbers: 0714NMC2066 0716NRT0711 07166DP2126
DIST-CO-RTE-PM07--134-7.9/7.9
Award Date05/01/2015
Closeout Date09/06/2018
Work DescriptionRemoval and installation of curb median on glendale Ave. Bridge over 134 Fwy.Construct Curb ramps E/B on/off Ramps to Glendale Ave. W/B of ramps at Monterey Rd. along Glendale Ave.& Monterey Rd. Restripe Glendale /Monterey Rd.Upgrade traffic signals.DP is 716-6DP-2126
Location Description134 Fwy, Glendale
QA Service Level1 (Verified on 07/25/2016)

Sample Information

Sample Taken Date10/04/2016 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/12/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes12 From where was the sample collectedFabricator
First name of sampler or witnessed byKevin Last name of sampler or witnessed byChurchill
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameTNT Rebar Nucor Transportation Laboratory (TL) NumberC970911
Inspector Lot Number from the Transportation Laboratory (TL) FormL0214416 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)PL14104777, PL16101720, 002116
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size#4,5,5
Diameter of Hoop2'-2", 2'-8", 3'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor Cascade
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2016-10-04-11
DIME Test ID: 2016-10-04-11-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-10-13

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 10/12/2016
UTM: 75KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12 2\'-8\"1#5/16mm0.3131138100440necking okayBrian

General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
WARNING: No graph data imported from Instron machine.

Test was verified on 10/13/2016