Summary for Test 2016-10-04-8-10

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211068
DEA: 080N5504
EFIS: 0800020102
DIST-CO-RTE-PM08-SBD-40-R105.2/R106.5
Award Date04/21/2016
Closeout Date08/09/2018
Work DescriptionREPLACE THE LEFT WATSON WASH BRIDGE N0. 0805L
Location DescriptionNot set
QA Service Level1 (Verified on 05/10/2016)

Sample Information

Sample Taken Date10/04/2016 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/10/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes16 From where was the sample collectedFabricator
First name of sampler or witnessed byKevin Last name of sampler or witnessed byChurchill
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) NumberC970913
Inspector Lot Number from the Transportation Laboratory (TL) FormL0214616 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)247516
Hoop Manufacturer Lot Number(s)1, 3, 9, 14 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop1'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerTNT
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2016-10-04-8
DIME Test ID: 2016-10-04-8-10
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-10-12

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 10/11/2016
UTM: 75KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
129#5/16mm0.312966195680Bar Broke in Heat Affected AreaBrian

General comments (publicly viewable) (Max 1000 characters): Bar Broke in Heat Affected Area
Test Graph
WARNING: No graph data imported from Instron machine.

Test was verified on 10/12/2016