Summary for Test 2016-10-05-7-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 210570
DEA: 100Y90U4
EFIS: 1015000055
DIST-CO-RTE-PM10-SJ-99,15,163-18.4/23.0
Award Date12/04/2015
Closeout Date04/11/2017
Work DescriptionPLACE JPCP (RSC), COLD PLANE AC PAVEMENT, AND INSTALL RAMP METERING.
Location DescriptionSAN JOAQUIN COUNTY IN STOCKTON FROM 0.1 MILE SOUTH OF MARSH STREET PEDESTRIAN OVERCROSSING TO 0.1 MILE NORTH OF HAMMER LANE OVERCROSSING
QA Service Level1 (Verified on 09/23/2015)

Sample Information

Sample Taken Date10/05/2016 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/07/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byGreg Last name of sampler or witnessed byThompson
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameMission City Rebar Transportation Laboratory (TL) NumberC836026
Inspector Lot Number from the Transportation Laboratory (TL) FormB914216 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)SE15100044
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop3'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerMission City Rebar
Welding CompanyMission City Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2016-10-05-7
DIME Test ID: 2016-10-05-7-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-10-12

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 10/10/2016
UTM: 75KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111#5/16mm0.312920894220necking okayBrian

General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
WARNING: No graph data imported from Instron machine.

Test was verified on 10/12/2016