Summary for Test 2016-09-29-9-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211723
DEA: 120N8804
EFIS: 1214000126
MINOR: 12A1641
DIST-CO-RTE-PM12-ORA-405-1.12
Award DateNot set
Closeout Date06/21/2021
Work DescriptionReplace safety lighting standards and refresh Signing and Striping for the SB 405 off ramp at Irvine Center Drive
Location DescriptionIRVINE, SOUTHBOUND RTE 405, AT EXIT RAMP TO IRVINE CENTER DRIVE
QA Service Level1 (Verified on 09/12/2016)

Sample Information

Sample Taken Date09/29/2016 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/03/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes1 From where was the sample collectedFabricator
First name of sampler or witnessed byKevin Last name of sampler or witnessed byChurchill
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameTNT Rebar Nucor Transportation Laboratory (TL) NumberC970905
Inspector Lot Number from the Transportation Laboratory (TL) FormL0213216 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)PL14104777
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2016-09-29-9
DIME Test ID: 2016-09-29-9-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-10-05

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 10/04/2016
UTM: 75KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
121#4/13mm0.21911795580Bar Broke in Heat Affected AreaBrian

General comments (publicly viewable) (Max 1000 characters): Bar Broke in Heat Affected Area
Test Graph
WARNING: No graph data imported from Instron machine.

Test was verified on 10/5/2016