Summary for Test 2016-09-06-5-3
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 211703 Permit Numbers: 07156SN1269 0717NRD0101 |
---|---|
DIST-CO-RTE-PM | 07--101-13.6/13.6 |
Award Date | 06/30/2015 |
Closeout Date | 08/21/2018 |
Work Description | Install traffic signal, sidewalk, curbramp |
Location Description | Village at the Park Dr./Petit St. (Dawson Dr), Camarillo |
QA Service Level | 1 (Verified on 09/01/2016) |
Sample Information
Sample Taken Date | 09/06/2016 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/07/2016 |
Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar Hoops |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Tory | Last name of sampler or witnessed by | Mclaurin |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | TNT Rebar | Transportation Laboratory (TL) Number | C4677248 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L6724916 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4028299 |
Hoop Manufacturer Lot Number(s) | 1 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 5 |
Diameter of Hoop | 3'-2" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | CMC Rebar |
Welding Company | TNT Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2016-09-06-5
DIME Test ID: 2016-09-06-5-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-09-09
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 09/08/2016
UTM: 75KIP
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 3 | 1 | #5/16mm | 0.31 | 28631 | 92360 | necking okay | Brian |
General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
WARNING: No graph data imported from Instron machine.
Test was verified on 9/9/2016 ✔