Summary for Test 2016-09-06-3-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211703
Permit Numbers: 07156SN1269 0717NRD0101
DIST-CO-RTE-PM07--101-13.6/13.6
Award Date06/30/2015
Closeout Date08/21/2018
Work DescriptionInstall traffic signal, sidewalk, curbramp
Location DescriptionVillage at the Park Dr./Petit St. (Dawson Dr), Camarillo
QA Service Level1 (Verified on 09/01/2016)

Sample Information

Sample Taken Date09/06/2016 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/07/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byTory Last name of sampler or witnessed byMclaurin
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) NumberC4677243
Inspector Lot Number from the Transportation Laboratory (TL) FormL6724416 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)043916
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2016-09-06-3
DIME Test ID: 2016-09-06-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-09-08

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 09/08/2016
UTM: 75KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111#4/13mm0.21861393060necking okayBrian

General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
WARNING: No graph data imported from Instron machine.

Test was verified on 9/8/2016