Summary for Test 2016-08-09-6-2
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 209921 DEA: 073X8204 EFIS: 0713000218 |
---|---|
DIST-CO-RTE-PM | 07-LA-39-21.7,22.0 |
Award Date | 11/25/2014 |
Closeout Date | 09/06/2018 |
Work Description | REPAIR SLOPE FAILURE. |
Location Description | LOS ANGELES COUNTY AT 0.2 MILE NORTH OF CARPENTER CANYON BRIDGE AND AT 0.2 MILE SOUTH OF PEJSA CANYON BRIDGE |
QA Service Level | 1 (Verified on 01/06/2015) |
Sample Information
Sample Taken Date | 08/09/2016 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/12/2016 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | RICHARD | Last name of sampler or witnessed by | JOLUDOW |
Title of sampler | STRUCTURE REPRESENTATIVE | Telephone number of sampler | Unknown |
Laboratory sample identification | 938-08 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | ROBERTSONS | Transportation Laboratory (TL) Number | No 2 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | RTE 39 MOMENT SLAB |
Structure name | RTE 39 MOMENT SLAB |
Material Information
Material Type | Concrete | The concrete mix design number | SC675B38 |
---|---|---|---|
The truck number from where the sample was collected | 1567 | The batch plant ticket number from where the sample was collected | 2251134 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | PLANT |
A detailed description of where the material sample was collected | TRUCK | Where the material sample would have been placed if not sampled | LOCATION 2 RTE 39 MOMENT SLAB |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2016-08-09-6
DIME Test ID: 2016-08-09-6-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-09-06
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 09/06/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 112160 lb
Maximum load on cylinder 2: 113270 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 3941.0 psi
Compressive strength of cylinder 2: 3980.0 psi
Compressive strength (to nearest 10 psi): 3960 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/6/2016 ✔