Summary for Test 2016-08-30-1-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 208679
DEA: 100S1104
EFIS: 1000000229
COOP: 10406
DIST-CO-RTE-PM10-SJ-4,5-Var
Award Date12/16/2013
Closeout Date01/03/2019
Work DescriptionSR-4 FREEWAY EXTENSION
Location DescriptionIN SAN JOAQUIN COUNTY
QA Service Level1 (Verified on 03/25/2013)

Sample Information

Sample Taken Date08/30/2016 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/31/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes8 From where was the sample collectedFabricator
First name of sampler or witnessed byED Last name of sampler or witnessed byFleming
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHarris Salinas Transportation Laboratory (TL) NumberC739930
Inspector Lot Number from the Transportation Laboratory (TL) FormB1037616 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)582535
Hoop Manufacturer Lot Number(s)H01 H02 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop2'-2" Epoxy CoatedYes
Epoxy Coating ColorNA Rebar ManufacturerHarris Salinas
Welding CompanyHarris Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2016-08-30-1
DIME Test ID: 2016-08-30-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-08-31

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/31/2016
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
13H01#4/13mm0.21895094750Bar BrokeBrian

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 8/31/2016