Summary for Test 2016-08-18-10-4
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 210953 DEA: 120N3304 EFIS: 1213000197 |
---|---|
DIST-CO-RTE-PM | 12-ORA-5-12.8/21.6 |
Award Date | 01/06/2016 |
Closeout Date | 08/21/2018 |
Work Description | SLAB REPLACEMENT (RSC), GRIND & GROOVE CONC PVMT, RHMA-G PVMT |
Location Description | NB & SB RTE 5 FROM NB AVERY PARKWAYGORE POINT (PM 12.8) TO I-5/405 SEPARATION (PM 21.6).ROUTE 5/405 SEPARATION |
QA Service Level | 1 (Verified on 08/12/2016) |
Sample Information
Sample Taken Date | 08/18/2016 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/22/2016 |
Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar Hoops |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Churchill |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | TNT Rebar | Transportation Laboratory (TL) Number | C648121 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L0219516 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4049973 4028299 |
Hoop Manufacturer Lot Number(s) | 1 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 4 5 |
Diameter of Hoop | 26 32 38 | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | CMC |
Welding Company | TNT Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2016-08-18-10
DIME Test ID: 2016-08-18-10-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-08-24
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/24/2016
UTM: 400KIP
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | 1 2\'-8\" | #5/16mm | 0.31 | 29250 | 94350 | Bar Broke | Brian |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 8/24/2016 ✔