Summary for Test 2016-08-16-1-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 210244
DEA: 05492804
EFIS: 0500000576
DIST-CO-RTE-PM05-SLO-1-64.0/R66.9
Award Date05/27/2015
Closeout Date03/06/2019
Work DescriptionCONSTRUCT BRIDGES AND REALIGN TWO LANE HIGHWAY.
Location DescriptionSAN LUIS OBISPO COUNTY ABOUT 9 MILES NORTH OF SAN SIMEON FROM PIEDRAS BLANCAS LIGHTHOUSE ROAD TO ARROYO DE LA CRUZ BRIDGE
QA Service Level1 (Verified on 06/23/2015)

Sample Information

Sample Taken Date08/16/2016 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/17/2016
Sample typeQuality Assurance A brief description of the sampleService Splice Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed bySamuel Last name of sampler or witnessed byEiler
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationLot 1 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameFlat Iron Steel Dayton Superior Transportation Laboratory (TL) NumberC868360
Inspector Lot Number from the Transportation Laboratory (TL) FormN/A Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCascade Steel
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size9 Coupler ModelD310
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)15202151 Rebar Heat Number(s)174416 174916
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2016-08-16-1
DIME Test ID: 2016-08-16-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2016-08-18

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/18/2016
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
13#9/29mm109828998289Service SpliceBrian

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 8/18/2016