Summary for Test 2016-08-11-3-1
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 210888 DEA: 072750U4 EFIS: 0715000283 |
---|---|
DIST-CO-RTE-PM | 07-VEN-33,101-0.9/T5.82.3/13.8 |
Award Date | 03/14/2016 |
Closeout Date | 07/23/2019 |
Work Description | CONSTRUCT STORM WATER TREATMENT BMP. |
Location Description | CONSTRUCT STORM WATER TREATMENT BMP. |
QA Service Level | 1 (Verified on 10/15/2015) |
Sample Information
Sample Taken Date | 08/11/2016 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/16/2016 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | PANTALEON | Last name of sampler or witnessed by | RIVERA |
Title of sampler | NP | Telephone number of sampler | 805-906-1656 |
Laboratory sample identification | 939-SRL23 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | GRIMES CANYON | Transportation Laboratory (TL) Number | 23 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | S72500 |
---|---|---|---|
The truck number from where the sample was collected | NP | The batch plant ticket number from where the sample was collected | NP |
Concrete batch plant | NP | The fabricator/manufacturer designation for the sample | NP |
A detailed description of where the material sample was collected | NP | Where the material sample would have been placed if not sampled | TORN RIVERA POC |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2016-08-11-3
DIME Test ID: 2016-08-11-3-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-08-16
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Jose Mendez
Date of test: 08/16/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 87990 lb
Maximum load on cylinder 2: 84640 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 5 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 3112.5 psi
Compressive strength of cylinder 2: 2994.0 psi
Compressive strength (to nearest 10 psi): 3050 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/16/2016 ✔