Test 2016-07-26-9-2 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 8196
DEA: 59912684
DIST-CO-RTE-PM59---
Work Description
Location Description
Sample Information
Sample Taken Date7/26/2016 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/29/2016
Sample typeRecertification A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes8 From where was the sample collectedFabricator
First name of sampler or witnessed byED Last name of sampler or witnessed byFleming
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameMission City Rebar Transportation Laboratory (TL) NumberC715259
Inspector Lot Number from the Transportation Laboratory (TL) FormB1030316 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)SE15102567
Hoop Manufacturer Lot Number(s)NA Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop2'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyMission City Rebar Coating StandardsUncoated
Weld TypeFlash Welded
Test Details
DIME Sample ID: 2016-07-26-9
DIME Test ID: 2016-07-26-9-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)
Test Release Date: 2016-08-29
Test Results

Number of Samples Tested: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 08/16/2016
UTM:400KIP
Temperature:72 F
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1Cycle-2100#5/25mmJanda #188010.313023497529Bar Broke in Heat Affected AreaFred

General comments (publicly viewable) (Max 1000 characters): Bar Broke in Heat Affected Area
Test Graph
Source: Partner Data Point File

Test was verified on 08/29/2016