Test 2016-07-16-1-6 (ASTM E23-12c) Summary

Project Information
Project IdentifiersProject ID: 3807
DEA: 07121844
EFIS: 0700000117
DIST-CO-RTE-PM07-LA-5-42.8/47.3
Work DescriptionCONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING
Sample Information
Sample Taken Date7/16/2016 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/26/2016
Sample typeQuality Assurance A brief description of the sampleCheck Sample Plates
The quantity of what the sample constitutes12 From where was the sample collectedFabricator
First name of sampler or witnessed byRussel Last name of sampler or witnessed byLynch
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameStinger Bridge Iron Transportation Laboratory (TL) NumberC952637 thru C952648
Inspector Lot Number from the Transportation Laboratory (TL) FormL9607216 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM6 - Steel Check Sample Plate Heat Number(s)2U133-403, 2U025-902, 2U036-503, 2U229-203, 2
Material SpecificationA709 Grade50
Thickness.5in .625in 1in 1.25in ShapeSquare
Metal Foundry Manufacturer (Mill)EVRAZ Plate Dimension12in x 12in
Test Details
DIME Sample ID: 2016-07-16-1
DIME Test ID: 2016-07-16-1-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM E23-12c: Standard Test Methods for Notched Bar Impact Testing of Metallic Materials (Charpy Impact)
Test Release Date: 2016-08-09
Test Results

Input Type: Measured
Tester's full name: Glen Weldon
Date of test: 08/04/2016
Temperature Required: 40 oF
Minimum Energy Required: 25 ftlb
Test Temperature 1: 39.9 oF
Impact Energy 1: 104 ftlb
Impact Energy 2: 99 ftlb
Impact Energy 3: 86 ftlb
Striker Radius: 8 mm
Average Impact Energy:96 ftlb
Value Exceeds The Machine Capacity?:No
General comments (publicly viewable) (Max 1000 characters): Heat 2T740

Test was verified on 08/09/2016