Summary for Test 2016-07-29-13-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 210698
DEA: 11299204
EFIS: 1100000422
DIST-CO-RTE-PM11-SD-94,805-Var
Award Date10/13/2015
Closeout Date09/10/2018
Work DescriptionSEISMIC RETROFIT 4 BRIDGES ON ROUTES 94 AND 805.
Location DescriptionIN SAN DIEGO COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 01/13/2016)

Sample Information

Sample Taken Date07/29/2016 Sample Unique Key13
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/02/2016
Sample typeQuality Assurance A brief description of the sampleHRC Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byCarlos Last name of sampler or witnessed byLopez
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHRC Cascade Transportation Laboratory (TL) NumberC958031
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCascade
Coupler ManufacturerHRC Intermediate Assembler or FabricatorUnknown
Rebar Size7 Coupler ModelHRC 500-510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)A153919 Rebar Heat Number(s)126016
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2016-07-29-13
DIME Test ID: 2016-07-29-13-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2016-08-04

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 08/03/2016
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12NA#7/22mm0.605711895197OK NeckingFred

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 8/4/2016